Seismic resilience of buildings
Seismic-resistance structure, seismic-damping structure, and seismic-isolation structure, and seismic grade
SCROLL DOWN
Dozens of plates of rock cover the earth. Intense strain and stress build up along boundaries where these plates meet. An earthquake occurs when the stress energy is suddenly released. Because Japan lies just above the borders of four earth plates, it is subject to thousands of earthquakes a year and thus is considered to be one of the world’s most earthquake-prone countries.
The seismic design regulations in the Building Standard Law of Japan have been amended repeatedly, based on the latest information obtained from building damage and relevant experience from past major earthquakes.
We listen to clients to understand their goals, and we propose the best suited seismic design for each and every building. Our designs are in full compliance with the seismic design regulations that are uniform nationwide, and we incorporate state-of-art knowledge obtained from our own advanced research for issues such that the regulations do not clearly specify.
In the following sections, we briefly describe how an earthquake effects a building and the three main systems to protect a building from an earthquake, and what seismic grade and performance-based design are. The performance-based design has been our structural engineering philosophy that we have been practicing since late ‘90s, when this term was not so common in the building design field.
What causes damage in buildings in the event of an earthquake?
Three Types of Seismic Structures for Protecting Buildings from Earthquakes
Seismic-resistant Structure
A seismic-resistant structure withstands earthquakes by means of the strength and stiffness of the columns, beams and walls that comprise the main frame. Because the energy of earthquakes is reacted simply and directly by the structure, the building undergoes a deformation as large as the earthquake. Therefore, the structural main frame will sustain damage depending on the scale of the earthquake. Detailed post-earthquake inspection is required to clarify the building damage, and necessary repairs should be made as far as is practical.
For seismic-resistant structures, it is important to place walls and such in appropriate positions in order to achieve the required seismic performance cost effectively. This structural system is the most widely used, from small-scale dwellings to high-rise buildings.
Seismic-damping Structure
A seismic-damping structure absorbs earthquake energy with damping components (dampers) installed in buildings. Thus, much less earthquake energy hits the main frame, and the damage to the main frame is reduced. Typically, dampers do not need to be replaced after a major earthquake. Even if they are damaged, they can be repaired or replaced individually. This makes the system relatively easy to restore to pre-earthquake conditions.
Owing to the effects of the dampers, these structures undergo significantly smaller vibration and deformation than the seismic-resistant structure. It is also possible to make dampers effective against wind-induced motion. The vibration control by damping has a variety of forms, such as unbonded braces, applicable to small to medium scale buildings, or the precast concrete central column of Tokyo Skytree® that works as a tuned mass damper.
Seismic-isolation Structure
In a seismic isolation structure, isolators are used to separate the building from the ground so that it floats while dampers absorb the earthquake energy. As earthquake energy is absorbed by dampers at the seismic isolation layer before it goes into the structure, damage to the building itself is mitigated more effectively. The dampers typically do not need to be replaced after a major earthquake. However, if investigation of the extent of the damage reveals that the performance has deteriorated, pre-earthquake conditions can be restored by repairing and replacing the dampers.
Although seismic isolation structures can reduce building sway and deformation more than seismic-resistant and seismic-damping structures, the initial setup cost is on the slightly higher side, due to the additional costs for the seismic isolation layer construction, seismic isolation components, and seismic expansion joints. However, the greater the number of stories, the smaller the cost increase ratio becomes. A seismic isolation structure can achieve better seismic performance as well as allowing designers more freedom in architectural planning compared to the other seismic systems.
As a seismic-isolation structure sways slowly during earthquakes, it keeps furniture and fittings from falling, lessening damage. Post-earthquake building functions can also be sufficiently maintained. In recent years, more and more buildings are adopting this structure even in large-scale buildings.
Performance Based Design
Considering business continuity planning (BCP) in the event of a major earthquake and frequent aftershocks, securing the main frame of the structure is often not sufficient. Nonstructural components must be secured as well, such as preventing falloff, measures for emergency power supply and other issues.
What is the Seismic Grade?
The seismic grade defines the levels of seismic performances required for the building. We decide the seismic grade for each building to meet the objectives of the owners, considering the scale and type of building and the users. In addition to the evaluation of seismic performance under the seismic intensity required by the regulations, we always simulate events of earthquakes greater than the code requirement to control the ultimate structural performance under such an extremely rare major earthquake.
Here we explain seismic grade using a damage scenario for a major earthquake with seismic intensity of around 6.
There are three grades: standard, high, and special.
- Standard: In buildings with the minimum seismic performance stipulated by the Building Standard Law, deformation affecting the framework remains, and serious damage can result from aftershocks. In addition, finishing materials sustain considerable damage or fall off. Evacuation is mandatory, and business activities cannot be maintained.
- High: Although some deformation of the framework remains and strength is deteriorated, the building will not collapse in aftershocks. The finishes and such sustain some damage. Functions necessary for the minimum business activities are secured, and the building can also be used as a temporary refuge.
- Special: Damage is minor, and almost no deformation to the framework remains. The finishes and such sustain slight damage, but basically there are no major problems. Business can also operate immediately.